Your cart is currently empty!
BTW, DOWNLOAD part of TestValid CDCP dumps from Cloud Storage: https://drive.google.com/open?id=1uJzdoK3ARr_pv5vOCXErwf3cafFV0Hku
The TestValid is the top-rated website that offers real Certified Data Centre Professional (CDCP) CDCP exam dumps to prepare for the EXIN CDCP test. TestValid has made these latest CDCP practice test questions with the cooperation of the world's highly experienced professionals. Countless CDCP Exam candidates have used these latest CDCP exam dumps to prepare for the EXIN CDCP certification exam and they all got success with brilliant results.
We should formulate a set of high efficient study plan to make the CDCP exam dumps easier to operate. Here our products strive for providing you a comfortable study platform and continuously upgrade CDCP test prep to meet every customer’s requirements. Under the guidance of our CDCP Test Braindumps, 20-30 hours’ preparation is enough to help you obtain the EXIN certification, which means you can have more time to do your own business as well as keep a balance between a rest and taking exams.
Considering your various purchasing behaviors, such as practice frequency. Occasion, different digital equivalents, average amount of time on our CDCP practice materials, we made three versions for your reference, and each has its indispensable favor respectively. All CDCP guide exam can cater to each type of exam candidates’ preferences. The three kinds are PDF & Software & APP version. Besides, we have always been exacting to our service standards to make your using experience better. We are exclusive in CDCP training prep area, so we professional in practice materials of the test.
NEW QUESTION # 89
Which one of the following is a core objective of a Business Value in an organization?
Answer: A
Explanation:
According to the EPI Data Centre Professional (CDCP) Reference Materials, a core objective of a Business Value in an organization is to create value for customers and stakeholders1. This means delivering products or services that meet or exceed customer expectations, while also generating profits or benefits for the organization and its shareholders. Reducing costs, reducing the deficit, and increasing sales are possible ways to achieve this objective, but they are not the core objective itself.
References: 1: EPI Data Centre Professional (CDCP) Reference Materials, page 9.
NEW QUESTION # 90
When having two non-synchronized power sources, the ATS / STS need to be of the type:
Answer: C
Explanation:
When having two non-synchronized power sources, the ATS / STS need to be of the type break before make, which means that the switch disconnects from one source before connecting to the other source. This prevents any short circuit, back feed, or phase mismatch that could occur if the two sources were connected simultaneously. Break before make switches are also known as open transition switches, because they create a brief interruption in the power supply during the switching process. This interruption is usually acceptable for most ICT equipment, as they have internal power supplies or batteries that can handle the transient. However, if the interruption is not acceptable, then the two power sources need to be synchronized before switching, which requires a make before break switch, also known as a closed transition switch. Make before break switches connect to the second source before disconnecting from the first source, which ensures a seamless transfer of power without any interruption. However, make before break switches require that the two sources have the same voltage, frequency, and phase, which can be achieved by using a synchronization module or a phase-locked loop.
References:
1: CDCP Preparation Guide, page 17, section 2.3.1 2: STS in data centres - Borri3, page 1, section 1 4: Using Static Transfer Switches to Enhance Data Center ... - Donwil5, page 1, section 1 6: What is an Automatic Transfer Switch (Power)? | Ethan Banks7, page 1, section 1
NEW QUESTION # 91
systems are designed specifically to protect the structure of a building.
Answer: D
Explanation:
Water sprinkler systems are designed to protect the structure of a building from fire by suppressing or extinguishing the flames with water. Water sprinkler systems are typically installed in the ceiling or walls of a building and are activated by heat or smoke detectors. Water sprinkler systems can reduce the risk of fire spreading and causing structural damage to the building.
References:
*EPI Data Centre Professional (CDCP) Preparation Guide, page 28
*Fire Protection Systems for Data Centers | EPI
NEW QUESTION # 92
Starting from which Rating does the requirement of Concurrently Maintainability becomes relevant?
Answer: C
Explanation:
The requirement of Concurrently Maintainability becomes relevant starting from Rated-3, according to the Uptime Institute Tier Classification System1. Concurrently Maintainability means that any component or system in the data centre can be maintained or replaced without affecting the availability of the IT equipment.
This requires having redundant capacity components and multiple independent distribution paths serving the IT equipment. Rated-3 data centres are designed to achieve Concurrently Maintainability and have a minimum uptime of 99.982%. Rated-4 data centres also have Concurrently Maintainability, but they also have Fault Tolerance, which means that they can withstand any single unplanned event without affecting the availability of the IT equipment. Rated-4 data centres have a minimum uptime of 99.995%. Rated-1 and Rated-2 data centres do not have Concurrently Maintainability, as they have only one distribution path serving the IT equipment and no redundant capacity components. Rated-1 data centres have a minimum uptime of 99.671% and Rated-2 data centres have a minimum uptime of 99.741%.
References:
1: Uptime Institute Tier Classification System2, page 1, section 1 2: Data Center Tiers Classification Explained: (Tier 1, 2, 3, 4)3, page 1, section 1 3: Data Center Tier Standards4, page 1, section 1
NEW QUESTION # 93
Cost of Downtime can be classified as.
Answer: C
Explanation:
Cost of downtime is the total amount of money lost due to a data centre outage or disruption. It can be classified into two categories: direct and indirect. Direct costs are the immediate and measurable expenses incurred during or after an outage, such as lost revenue, lost productivity, recovery costs, compensation costs, penalties, etc. Indirect costs are the long-term and intangible impacts of an outage, such as reputation damage, customer dissatisfaction, loss of market share, legal liabilities, etc. Both direct and indirect costs can vary depending on the type, duration, and severity of the outage, as well as the industry, size, and location of the data centre.
References:
*EPI Data Centre Training Framework1
*EPI Data Centre Competence Framework2
*Understanding the Cost of Data Center Downtime3
*Uptime Institute's 2022 Outage Analysis Finds Downtime Costs and Consequences Worsening
*[INFOGRAPHIC] The Cost of Downtime: 21 Stats You Need to Know
NEW QUESTION # 94
......
There are three versions of CDCP training materials for the candidate of you, and different versions have different advantages, you can use it in accordance with your own habit. Free update for each version for one year, namely, you don’t need to buy the same version for many times, and the update version will send to you automatically. You will get the latest version of CDCP Training Materials.
CDCP Exam Torrent: https://www.testvalid.com/CDCP-exam-collection.html
It is the dream of every certification candidate to crack the Certified Data Centre Professional (CDCP) CDCP examination on the first sitting, EXIN Test CDCP Questions Security of information: Our top of the line security tools make us one of a kind in this field, People who are confident about their knowledge and expertise can take these CDCP practice tests and check their scores to know where they lack, So our CDCP pass4sure cram is your best choice among other similar products.
How Can the Function Call Operator Help with CDCP Test Registration Functionoids, What does this mean for those seeking to remain current with their certifications, It is the dream of every certification candidate to crack the Certified Data Centre Professional (CDCP) CDCP examination on the first sitting.
Security of information: Our top of the line CDCP security tools make us one of a kind in this field, People who are confident about their knowledge and expertise can take these CDCP practice tests and check their scores to know where they lack.
So our CDCP pass4sure cram is your best choice among other similar products, TestValid's EXIN CDCP web-based and desktop practice tests provide you with an EXIN actual test scenario, allowing you to experience the CDCP final test conditions.
BTW, DOWNLOAD part of TestValid CDCP dumps from Cloud Storage: https://drive.google.com/open?id=1uJzdoK3ARr_pv5vOCXErwf3cafFV0Hku